Aviary Court, Wade Road, Basingstoke, Hampshire, RG24 8PE UK

PA-470L
Description
Quad Element Wall Mount PIR Sensor:
16m (53ft) Wide Angle / 20m (66ft) Long Range
QUAD ELEMENT+ NEW FUZZY LOGIC PROCESSING SYSTEM:
"Fuzzy Logic" is the state-of-the-art processing system that simulates the human decision process as it compares various information such as size, temperature differential, etc. to determine the criteria for an alarm condition. This reduces false alarm while maintaining a high detection capability.
PATTERN SELECTABLE WITH INTERCHANGEABLE LENS:
Wide angle / long range pattern is selectable during installation by convenient fresnel lens replacement. Spare long range lens is included in package. Zone changeover switch sets the detection pattern to match the lens pattern when lens is changed.
TROUBLE ALARM (LOW VOLTAGE):
When sensor detects a drop in supply voltage,the alarm relay and LED latches in alarm until voltage is restored to its proper level.
ALARM MEMORY:
Units contain special circuitry to indicate an alarm has been activated during armed period. Especially useful when more than one unit is used per zone.
REMOTE LED CONTROL:
Allows the LED to be enabled/disabled via the control panel.
- Alarm LED disable (ON/OFF)
- Alarm contact selectable (N.C./N.O.)
- Sensitivity adjustment (60%, 80%, 100%, 120%)
- Zone changeover (Wide angle/long range)
Features
- Includes Wide Angle & Long Range lenses
- Fresnel lens with Look-Down Zone
- Tamper Circuit, Alarm Memory
- Sensitivity adjustment 60% to 120%
Details
Specifications
Downloads
| Model | PA-470L |
| Product type | Passive infrared sensor |
| Detection system | Passive infrared (Quad: fuzzy logic) |
| Coverage | Wide angle: 16m (53ft) max. Long range: 20m (66ft) max. |
| Sensitive zones | Wide angle: 22 pairs (88) Long range: 2 pairs (8) |
| Mounting positions | indoor wall/pillar |
| Supply voltage | 9 to 18VDC (non-polarity) |
| Current consumption | 28mA max. |
| Alarm output | Dry contact relay (NO/NC selectable) Reset: approx. 2 sec, 30V, 0.25A max. (Protective resistance 3.3Ω built-in) |
| Tamper output | Dry contact (NC) 30V, 0.1A max. |
| Alarm LED (Red) | Blinking at warm-up Lighting at alarm Lighting at memory activated Lighting at trouble alarm (LED disable) |
| Memory control | Controls memory indication/reset with terminal M/C |
| LED control | Controls alarm LED indication with terminal L/C |
| Trouble alarm | Low power voltage: monitors drop in power voltage Operate: initiate trouble alarm |
| Ambient temperature | -10°C to +50°C (+14°F to +122°F) without condensation |
| Wiring | Terminals |
| Weight | 165g (5.8oz) |
| Accessory | Fixing screw: 4x30 2pcs Long range lens |